IPT 20 - TECHNICAL DATA
Maximum starting pressure
1 Pa
Operating range
10
-2
- 10
-9
Pa
Ultimate pressure
10
-9
Pa
Anode voltage
- 6 kV
Magnetic induction between poles
0.12 T
Pumping speed for N
2
AT 10
-4
Pa
20 l/s
Connection flange
DN 40 CF
Weight
11.5 kg
Maximum leakage current